| Overview |
|
Put Your NIBP Monitors To The Test With The Most Trusted Analyzer On The Market. Truly reliable performance is what more than 2,000 registered users worldwide have come to expect from our CuffLink Non-Invasive Blood Pressure (NIBP) Analyzer. They’re not alone. Medical device manufacturers around the world also trust the CuffLink to deliver dynamic oscillometric non-invasive blood pressure waveforms again and again, with 1% repeatability! How does CuffLink meet this challenge? By offering you a quick, reliable, and consistent way to evaluate the operation and performance of all types of oscillometric NIBP monitors on the market. The demand for repeatability is the cornerstone upon which the CuffLink was originally developed. We were first to market with this new technology, and we continue to keep pace with ongoing advancements. For you, this means an investment in technology that not only meets your NIBP monitor testing needs today, but will continue to meet future requirements. Whether you are a biomedical or clinical engineering professional within a hospital, or a manufacturer of medical devices, DNI’s CuffLink NIBP Analyzer represents a solid investment. Physiologically Accurate Signals CuffLink’s NIBP waveforms are based upon actual human physiological parameters, so you can be sure you are simulating a stable, "live patient" response to the patient cuff. Plus, CuffLink further ensures data integrity by analyzing measurements independent of the inflate/deflate cycle or the interpretive algorithm used by the NIBP monitor. You get a consistent and repeatable source of NIBP signal, complete with variable systolic/diastolic values and adjustable heart rates… just like a real patient! The Full Spectrum Use CuffLink to simulate the full range of normal, hypertensive, and hypotensive dynamic NIBP waveforms representing typical adult, infant, and neonatal patients. You can also generate normal, bradycardia, and tachycardia rhythm selections with a wide range of weak, normal, and strong peripheral pulses. Each selection is user-programmable. You can easily simulate just about any patient condition, including, for example, mild or strenuous exercise. With CuffLink, your NIBP monitor will actually think there is a real patient attached to the cuff! Neonatal Blood Pressure Simulation With a fast 80 millisecond rise time and heart rates up to 240 beats per minute, CuffLink allows you to simulate neonatal non-invasive blood pressures as easily as adult ones. All the cuff mandrels and tubing adapters you will need to fit these small neonatal cuffs are standard CuffLink accessories. |
| Features |
|
» Dynamic Oscillometric Non-Invasive Blood Pressure simulation
» Automated static pressure measurements, leakage testing, and relief-valve testing » 5 automated NIBP testing autosequences » 5 Arrhythmia selections » Adult and Neonatal NIBP selections » Adjustable heart rate values » Interfaces directly with medTester 5000C |
| Specifications |
|
Power
» 115/230 VAC, 50 watts average, 100 watts peak, 50/60 Hz Analog Outputs » Cuff Pressure: 0 to 300 mmHg FS, 10 mV/mmHg » Pulse Pressure: 0 to 5.0 mmHg FS, 1.0 V/mmHg Digital Manometer » Pressure Range: -499.75 to 499.75 mmHg » Measurement Parameters: Instantaneous and peak » Input Overpressure Limit: ± 1500 mmHg Displayed Graphics » Dynamic Real-Time NIBP Cuff Pressure waveform programmed peripheral pulse and envelope waveforms. Display » Full Alphanumeric/Graphic Display (LCD) » Alphanumeric Mode: 8 lines x 40 characters » Graphics Mode: 64 vertical x 240 horizontal dot matrix backlight with viewing angle adjustment Digital Interfaces » RS-232C/Serial: Bi-directional. Downloads cuff measurement data and controls test features with a compatible computer or via the medTester 5000B with the medCheck option. » Parallel/Printer: Centronics compatible » Pulse Sync: 0 to 5 VDC (TTL) Cuff Mandrel » Interlocking Plastic Blocks - Four cuff circumferences of 39.5 cm (large adult), 33 cm (adult), 26.6 cm (small adult) and 20 cm (child). Maximum cuff width: 15.25 cm » Truncated Plastic Cylinder - Three neonatal cuff circumferences of 14 cm, 10 cm, 7.6 cm. Maximum cuff width: 7.6 cm Pop-Off Valve Testing » Automatically tests operation of the monitor’s relief valve » Measurement Parameters: Instantaneous and peak pressure » Maximum Pressure: 499.75 mmHg » Input Overpressure Limit: 1500 mmHg System Leak Testing » Start Pressure: 499.75 mmHg maximum » Elapsed Time: 60 seconds (fixed) » Leak Rate Range: 0.25 to 499.75 mmHg/minute » Input Overpressure Limit: ± 1500 mmHg Accuracy » Systolic/Diastolic (mean) Arterial Pressure: Based on preprogrammed set points on oscillometric pulse envelope » Static Pressure: ± 1.0% of reading, ± 1 mmHg Cuff Adapters » Cuff adapters insert between the NIBP device, cuff, and analyzer. These adapters are compatible with most current oscillometric NIBP monitors. - Male/Female LUER Locking - Female/Male LUER Non-Locking Taper - Male/Male Hose Barb (large 5/32 in) - Male/Male Hose Barb (small 1/8 in) - Male Hose Barb to Hose Extension (IVAC) - Male/Female Clippard (Criutikon, Siemens) - Colder/CPU (Marquette, Protocol) - OBAC Quick Release (Hewlett Packard) Autosequences » User can program up to five sequences to test NIBP monitors with a specific series of CuffLink performance tests. These tests can include: - Static Pressure Test - Leak Test - Pop-Off Test » Dynamic NIBP Tests: Select up to eight of the Adult-Neonatal-Arrhythmia dynamic NIBP selections. Each selection can be cycled up to 99 times during the sequence. Test report with results can be printed. Displayed Real-Time Parameters » Instantaneous Cuff Pressure: 0.0 to 300 mmHg » Peak Cuff Pressure: 0.0 to 500 mmHg peak » Inflate/Deflate Time: 0.1 to 999.9 seconds » Inflate/Deflate Rate: 0.1 to 999.9 mmHg/second » Total Measurement Time: 0.0 to 999.9 seconds maximum » Selected Heart Rate: Selected Systolic/Diastolic (Mean) Target Values » User-Programmed Vertical and Horizontal Shifts Dynamic Non-Invasive Blood Pressure » Simulates the range of normal, hypertensive and hypotensive dynamic non-invasive blood pressures. These represent typical adult, infant, and neonatal patients. Generates normal, bradycardia, and tachycardia rhythm selections with a wide range of user-programmable weak, normal and strong peripheral pulse amplitudes. Compatible with oscillometric NIBP devices. » Preprogrammed Target Value Selections - Systolic/diastolic (MAP): 60/30 (40), 80/50 (62), 100/65 (75), 120/80 (90), 150/100 (115), 200/150 (165) and 255/195 (215) - Repeatability: ± 1% of selected target value » Adult Arrhythmia Selections - Baseline NIBP Target Value: (120/80) (NSR) - Atrial Fibrillation (A-Fib) - Premature Atrial Contraction (PAC) - Premature Ventricular Contraction (PVC) - Missed Beat (MB) - Aberrant Sinus Conduction (AS) » Preprogrammed Peripheral Pulse Waveforms - Pulse Amplitude @ MAP: 2.0 mmHg (typical adult value) - Pulse Volume Range: 0 to 5.1 mL - Pulse Rise Time: 80 msec (minimum) - Heart Rates: 30, 40, 60, 80, 120, 160, 200 & 240 BPM - Heart Rate Accuracy: ± 1.0% of selected rate » User Programmable Target Value Shifts - Horizontal Axis: Preprogrammed target value selections can be shifted in 1.0 mmHg steps over a maximum range of ± 100 mmHg to increase or decrease dynamic pressure values. - Vertical Axis: Relative amplitude can be shifted in 1% increments over a maximum range from 0 to 200% to simulate weak, normal, and strong peripheral pulses. Dimensions » 12.5 in W x 5 in H x 15 in L » (31.75 cm W x 12.7 cm H x 38.1 cm L) Weight » 15 lb (6.82 kg) |